AUM 09 sensor-controlled stainless steel washbasin

AUM 09 is a sensor-controlled stainless steel wall-mounted washbasin. The washbasin is equipped with sensor-controlled outlet arm. Water turns on automatically when the user’s hands are placed within the sensor’s range and turns off when they have been removed. Water stops running with a certain time delay after the hands have been removed from the scanning zone. The washbasin is equipped with a mechanism against excess pressure of hot and cold water.

Package contents

  • sink with sheathing
  • outflow arm
  • photocell head
  • electronics
  • electromagnetic valve
  • corner valve with filter (AUM 09.2, .TV – 2 pcs)
  • spherical valve (AUM 09.TV)
  • mixing valve (AUM 09.2)
  • thermostatic valve (AUM 09.TV)
  • through-flow water heater (AUM 09.E)
  • source of power supply ZAC E – 12 V, 50 Hz (AUM 09.E)
  • waste siphon
  • connecting hoses
  • small assembly materials
Product code Product name Price Price (VAT)
AUM 09.1 On demand On demand
AUM 09.1B On demand On demand
AUM 09.2 On demand On demand
AUM 09.2B On demand On demand
AUM 09.E On demand On demand
AUM 09.TV On demand On demand
AUM 09.TVB On demand On demand
Radius of sensor 0 – 0,3 m
Water inlet G 1/2“
Outlet d = 50 mm
Inner dimension of the washbasin 370 x 340 x 150 mm
Electricity protection IP 55
Adjustable time of water flow 0 – 4 sec. (adjusted to 1 sec.)
AUM 09.1, .2, .TV
Water pressure 0,1 – 1,0 MPa
Power supply 12 V, 50 Hz, or for battery versions 6V (4 x AA battery)
Power requirement 6 VA
Source of power supply ZAC 1/20 (max. 3 x AUM 09)
ZAC 1/50 (max. 8 x AUM 09)
Weight 9 kg
AUM 09.E
Water pressure 0,2 – 0,6 MPa
Recommended pressure 0,3 MPa (without variances and air bubbles)
Power supply 230 V, 50 Hz
Power requirement 3 500 W
Weight 10,5 kg
  • Set-up water inlet as per picture
  • Set-up outlet d = 40 mm
  • Set-up cable for power supply – 12 V, 50 Hz from source of power supply ZAC (does not apply to AUM 09.E)
  • Set-up cable CYKY 3C x 1,5 – 2,5 (for AUM 09.E)

    • A
      COLD WATER (AUM 09.2, .TV, E)
      MIXED WATER (AUM 09.1) Innerpipe G 1/2"

n

    • B
      HOT WATER (AUM 09.2, .TV) Inner pipe G 1/2"

n

    • C
      ELECTRICITY SUPPLY

n

    • D
      OUTLET

n

  • E
    ZONE OF SCANING