AUM 09 sensor-controlled stainless steel washbasin
AUM 09 is a sensor-controlled stainless steel wall-mounted washbasin. The washbasin is equipped with sensor-controlled outlet arm. Water turns on automatically when the user’s hands are placed within the sensor’s range and turns off when they have been removed. Water stops running with a certain time delay after the hands have been removed from the scanning zone. The washbasin is equipped with a mechanism against excess pressure of hot and cold water.
Package contents
- sink with sheathing
- outflow arm
- photocell head
- electronics
- electromagnetic valve
- corner valve with filter (AUM 09.2, .TV – 2 pcs)
- spherical valve (AUM 09.TV)
- mixing valve (AUM 09.2)
- thermostatic valve (AUM 09.TV)
- through-flow water heater (AUM 09.E)
- source of power supply ZAC E – 12 V, 50 Hz (AUM 09.E)
- waste siphon
- connecting hoses
- small assembly materials
Radius of sensor | 0 – 0,3 m |
Water inlet | G 1/2“ |
Outlet | d = 50 mm |
Inner dimension of the washbasin | 370 x 340 x 150 mm |
Electricity protection | IP 55 |
Adjustable time of water flow | 0 – 4 sec. (adjusted to 1 sec.) |
AUM 09.1, .2, .TV | |
Water pressure | 0,1 – 1,0 MPa |
Power supply | 12 V, 50 Hz, or for battery versions 6V (4 x AA battery) |
Power requirement | 6 VA |
Source of power supply | ZAC 1/20 (max. 3 x AUM 09) |
ZAC 1/50 (max. 8 x AUM 09) | |
Weight | 9 kg |
AUM 09.E | |
Water pressure | 0,2 – 0,6 MPa |
Recommended pressure | 0,3 MPa (without variances and air bubbles) |
Power supply | 230 V, 50 Hz |
Power requirement | 3 500 W |
Weight | 10,5 kg |
- Set-up water inlet as per picture
- Set-up outlet d = 40 mm
- Set-up cable for power supply – 12 V, 50 Hz from source of power supply ZAC (does not apply to AUM 09.E)
- Set-up cable CYKY 3C x 1,5 – 2,5 (for AUM 09.E)
-
- A –
COLD WATER (AUM 09.2, .TV, E)
MIXED WATER (AUM 09.1) Innerpipe G 1/2"
- A –
n
-
- B –
HOT WATER (AUM 09.2, .TV) Inner pipe G 1/2"
- B –
n
-
- C –
ELECTRICITY SUPPLY
- C –
n
-
- D –
OUTLET
- D –
n
- E –
ZONE OF SCANING