AUP R sensor-controlled flushing system for a group of urinals
AUP R is a sensor-controlled flushing system for a group of urinals using a photocell sensor for contactless control that reacts to people entering the scanning zone. After leaving the scanning zone the flushing system is activated.
The photocell sensor does not react to people passing by and is not sensitive to daylight and artificial lighting. After 24 hours inactivity the urinal flushes itself.
The AUP R sensor-controlled flushing system is intended for sanitary facilities and in operations with breaks – e.g. social sport facilities, stadiums and schools and where it increases the user’s comfort.
Package contents
- installation box of electronics
- installation box of the valve
- inlet and outlet bolting
- electronics
- electromagnetic valve
- covering assembly metal plate – 2 pcs
- mounting spacer tray – 2 pcs
- stainless steel casing of box of electronics
- stainless steel casing of the valve box
- reflective glass
- connecting cable between electronics and valve
- anchoring material
Radius of sensor | self-adjusting |
Water inlet | G 3/4” (1”) |
Water pressure | 0,1 – 1,0 MPa |
Adjustable time of flushing | 1 – 20 sec. (adjusted to 5 sec.) |
Power supply | 12 V, 50 Hz |
Power requirement | 6 VA |
Source of power supply | ZAC 1/20 (max. 3 x AUP R) |
ZAC 1/50 (max. 8 x AUP R) | |
Weight | 2,8 kg |
- Set-up alcoves
- 150 x 150 x 100 mm for setting up the installation box of the electromagnetic valve
- 150 x 150 x 70 mm for setting up box with electronics
- Set up the water inlet to the valve box and individual urinals
- Set up cable for power supply – 12 V, 50 Hz from source of power supply ZAC
-
- * –
zone of non-sensitivity of the sensor, aprox. 20% of set radius of sensor
- * –
n
-
- A –
water inlet – G¾“
- A –
n
-
- C –
electricity input
- C –
n
-
- E –
scanning zone
- E –
n
-
- K –
installation box with electronics
- K –
n
-
- R –
reflective glass
- R –
n
- V –
installation box with the valve