AMZ 01, AMZ 02 automatic washing system for aprons
AMZ is an automatic stainless steel washing system of aprons intended for free-standing onto the floor. The system of nozzles uses a single-pipe inlet of pre-mixed water from a circulation or water mixed by means of a thermostatic valve.
The AMZ 01 is equipped with a built-in sensor that reacts to a user standing within the range of its scanning zone. The user steps on the grid, the electromagnetic valve opens the water inlet and water starts to flow out from the system of nozzles. The apron is cleaned of dirt by means of the nozzles without the necessity of contact and thus prevents from the possible contamination of the control elements.
Water stops running with a certain time delay after the user steps off the grid. Regarding the construction of the washing system it is recommended to install the system close to the sewer inlets.
The AMZ 02 is a sensor-controlled washing system of aprons equipped with a START/STOP system. The user steps on the grid and turns on water by brief shading of the sensor. A hand brush with a connection to the water inlet can be used for additional cleaning. The washing system is equipped with a stainless steel water retainer with its own outlet, which is placed underneath the grid.
Package contents
- body of washing system
- stainless steel grid
- rear panel with nozzles
- electronics with photocell
- hand brush (AMZ 02)
- electromagnetic valve with filter)
- connecting hoses
- nozzles – 6 pcs
Radius of sensor | 0 - 0,7 m (AMZ 01) |
0 – 01 m (AMZ 02) | |
Water inlet | G 1/2“ |
Water pressure | 0,3 – 1,0 MPa |
Electricity protection | IP 55 |
Power supply | 12 V, 50 Hz |
Power requirement | 10 VA |
Source of power supply | ZAC 1/20 (max. 2 x AMZ 01) |
ZAC 1/50 (max. 5 x AMZ 01) | |
Water temperature | max. 42°C |
Weight | 32 kg AMZ 01 |
36 kg AMZ 02 |
- Set up water inlet as per picture
- Set up outlet d = 50 mm via effluvial cover
- Set up cable for power supply – 12 V, 50 Hz from source of power supply ZAC
- A –
water inlet inner pipe G 1/2"
- C –
electricity supply
- E –
zone of scaning
- G –
output nozzles
n
n
n