AUP 1 automatic flushing system of urinals

AUP 1 is an automatic flushing system of urinals. A photocell sensor reacts to people (subjects) entering the scanning zone. After leaving the scanning zone the flushing system is activated.
The photocell sensor does not react to people passing by and is not sensitive to daylight and artificial lighting. After 24 hours inactivity the urinal flushes itself. The rate of water flow can be adjusted by a spherical valve.
The automatic flushing system of the AUP 1 urinal is intended for social facilities where the user’s comfort and the maintenance of hygiene is required at maximum water savings.

Package contents

  • electromagnetic valve
  • stainless steel casing with box of electronics
  • mounting spacer tray
  • fittings

AP 1 – hose connection (press hose with braces, reductions and brass bolting with fixing points (see photo)

Product code Product name Price Price (VAT)
AUP 1 On demand On demand
Radius of sensor self-adjusting
Water inlet G 1/2“
Water pressure 0,1 – 1,0 MPa
Outlet as per type of urinal
Adjustable time of flushing 1 – 20 sec. (adjusted to 5 sec.)
Power supply 12 V, 50 Hz
Power requirement 6 VA
Source of power supply ZAC 1/20 (max. 3 x AUP 1)
ZAC 1/50 (max. 8 x AUP 1)
Weight 1,5 kg
  • Set-up alcove 150 x 150 x 70 mm for installation of the electromagnetic valve
  • Set-up water inlet G 1/2“ to AUP 1 for connection to the electromagnetic valve and water inlet to the valve of the urinal (e.g. AP 1)
  • Set-up outlet – as per siphon
  • Set-up cable for power supply – 12 V, 50 Hz from source of power supply ZAC

Urinal with upper water input

Urinal with upper water input

Urinal with rear water input

Urinal with rear water input

    • A
      water inlet inner pipe G 1/2"

n

    • C
      electricity supply Cabel CYKY 2Ax1,5

n

    • D
      outlet (as per siphon)

n

  • E
    zone of scaning

Manual

Manual