AUM 6 automatic awter tap with through-flow water heater CLAGE 3,5 KW – 230V, 50Hz

AUM 6 is an automatic sensor-controlled tap with a Clage 3,5 kW through-flow water heater. Water turns on automatically when the user’s hands are within the sensor’s range and turns off when they have been removed. Water keeps on running for a short period of time after the hands have been removed from the scanning zone – after-flow delay time. The water stops flowing automatically if the sensor has been screened for longer than 30 seconds.
The advantage of the AUM 6 tap is the swift rise in the temperature of the running water. Temperature setting of running water is carried out by means of a positioning bolt on the heater.
The automatic sensor-controlled AUM 6 tap meets EU standards and is intended for washbasins, for example in cloakrooms or toilets in administrative departments, public facilities and shops where the user’s comfort and the maintenance of hygiene is required at maximum water savings.

Package contents

  • through-flow heater
  • outflow arm
  • stainless steel casing
  • case with electronics and transformer
  • electromagnetic valve
  • corner valve
  • connecting hoses
  • electric cable with forked end
  • fittings
Product code Product name Price Price (VAT)
AUM 6 On demand On demand
Radius of sensor self-adjusting
Water inlet G 1/2“
Water pressure 0,15 – 0,6 MPa (without variances)
Recommended pressure: 0,3 MPa (adjusting of water heater)
After-flow period 0 – 4 sec. (adjusted to 1 sec.)
Flow capacity 2 l/min when heated by 20°C
Maximum output temperature of water 50 °C
Time from start to stable state max. 7sec.
Power supply 230 V, 50 Hz
Power requirement 3 500 W
Inlet protection 16 A
Weight 3,5 kg
  • Set-up water inlet, pipe 1/2“ – as per picture
  • Set-up electricity power supply – socket 230V, 50 Hz
  • Placing the socket in accordance with ČSN 33 2000-7-71 standard
  • Recommended distance between the water outlet and the socket is 300 – 700 mm

  • A
    hot water (inner pipe G1/2")
  • n

  • C
    elecricity supply
  • n

  • F
    possible placing of cable outlet
  • n

  • E
    zone of scaning

Manual

Data for projectants